If interconnected CO and Smoke/Heat Alarms are all sounding, the
LOCATE switch on the Ei411H3 Remote Control should be pressed. This
will just leave the alarm that triggered the system sounding.
This is very important to determine because the actions to take in each
situation are very different.
In the case of CO the premises should be fully ventilated by opening doors
and windows. The user should call the gas supplier etc.
In the case of fire, doors and windows should be closed to slow the spread
of fire. The user should call the fire brigade etc.
2. Wirelessly communicate with Ei Electronics RadioLINK accessories
such as the Ei428 RadioLINK Relay (e.g. for shutting off gas valves) and
the Ei411H3 Remote Control.
4.2.1 Interconnection
After all the RadioLINK devices have been installed they must all be house
coded as follows:
Housecoding your alarm
1. Press and hold the housecode switch on the bottom of the cover with a small screwdriver until the
green power light turns red (see figure 7).
2. Immediately release the switch and the light will flash red (alternating with green) quickly a few times.
The red light will then flash every 5 or 10 seconds (depending on number of units coded - see below).
Repeat this action on all other RadioLINK Ei262 units in the property as quickly as possible (within 15
minutes).
3. Now put any other RadioLINK devices in the property into house code mode (see their separate
instruction manuals for details) within 15 minutes.
18
HOUSECODE
SWITCH
GREEN POWER LIGHT TURNS
RED FOR RADIOLINK INDICATION
House
Code
Figure 7