Audible Alarm : 85dB(A) minimum @ 3m
Self Diagnostics
Sensor : Horn beep and amber fault light flashes every 40 seconds if a sensor fault is found.
Rechargeable : Fully charged cells can power unit in standby for over 4 weeks and without
Lithium Cells: mains power, it can power the unit in alarm for over 2 hours. The unit beeps
every 40 seconds if cells are depleted.
Tamperproof : Screwdriver needed to release from mounting plate. Additionally a tamper-
proofing screw can be fitted to the mounting plate.
Hardwired Interconnect : Up to 12 Ei262 CO Alarms can be interconnected, so that when one senses
CO, all alarm. Alternatively, up to a combined total of 12 Ei262 CO Alarms
and Ei161RC/Ei164RC/Ei166RC/Ei2110/Ei261RC Smoke/Heat/Fire Alarms
can be interconnected provided that an Ei1529RC Remote Control is used.
Wireless Interconnect : Up to 12 Ei262 CO Alarms can be interconnected, so that when one senses
CO, all alarm. Alternatively, up to a combined total of 12 Ei262 CO Alarms
and Ei161RC/Ei164RC/Ei166RC/Ei2110 Smoke/Heat/Fire Alarms on an
Ei168RC RadioLINK base can be interconnected provided that an Ei411H3
Remote Control is used.
CO Alarm Memory: : A unit will indicate if it has been in alarm previously by flashing the red light
for 2 seconds every 40 seconds (2 flashes for 50 ppm CO, 4 flashes for 100
ppm CO and 8 flashes, for 300 ppm CO). When the Test/Hush button is
pressed, the red light flashes (as per Table B) to indicate the previous CO
alarm level detected. The memory is cleared by holding down the Test/Hush
button until the red light stops flashing.