1. ALARM DOES NOT WORK WHEN THE TEST BUTTON IS PRESSED:
- Check that the green mains power light is on. If it is off check the wiring, fuse, circuit breakers etc.
- Hold the Test/Hush button down for at least 5 seconds.
- Turn off mains power, remove from mounting plate (see figure 4) for 3 minutes and re-install (this resets
the alarm).
2. ALARM BEEPS AND AMBER LIGHT FLASHES EVERY 40 SECONDS:
- If the alarm beeps and the amber fault light flashes every 40 seconds, the CO sensor is probably
defective.
- Press the Test/Hush button for approximately 20 seconds to reset the unit. If the beeping and the amber
light flashing re-occurs replace the sensor module.
3. ALARM BEEPS EVERY 40 SECONDS (without amber light flashing):
- Rechargeable cells depleted. Reconnect mains power if green light is off.
4. ALARM SOUNDS FOR NO APPARENT REASON:
Follow the detailed instructions in Section 1 on page 4 entitled “WHAT TO DO WHEN THE ALARM
SOUNDS”. If there are still problems:
- Ensure there are no fuel-burning appliances in the vicinity which could be leaking CO gas (e.g. even
from next door).
- Ensure there are no fumes in the area (e.g. paint, thinners, alcohol, hair spray, chemical cleaners
aerosol sprays etc).
- Ensure there is no outdoor source of CO in the vicinity (e.g. a car with engine running, heavy traffic,
heavy air pollution, barbecue fumes etc).
- Press the Test/Hush button to silence the alarm.