4. Check that the RadioLINK Ei262 is house coded to all the other RadioLINK devices in the property by
counting the number of times the red light flashes (alternating with the green) every 5 (or 10) seconds.
For example, with just the Ei262, on its own, in the “system” it will give one red light flash every 5 seconds,
with 3 units in the system should give 3 short flashes every 5 seconds, 4 units should give 4 short flashes
and so on, up to 12 units. It may take up to 30 minutes for all the units in the system to be House Coded
correctly. Check that the other RadioLINK units are house coded as per their instructions. If at the end
of this period certain units do not show the correct number of flashes, repeat the process (from point 1
above) once more and if this fails see - Section 14 Troubleshooting on page 36.
5. The units will automatically exit the House Code learn mode after 30 minutes however we recommend
that you manually exit the House Code mode by pressing and holding the House Code switch on the
Ei262 until the RadioLINK Indicator light turns red, and then release. The RadioLINK Indicator light
should stop flashing and an 'exit House Code' signal will be sent to all other units.
Check that the RadioLINK Indicator lights on all other units have stopped flashing red. (If some units are
still flashing it may indicate a problem with the radio communication from this unit to the other units, or
these devices may have to be taken out of house code mode manually, see their instruction manuals).
Repeat the process once more and if this fails see - Section 14 Troubleshooting on page 36. Manually
exiting the House Code mode reduces the risk of accidentally House Coding your RadioLINK devices
with nearby systems.
6. Check the communications by pressing the test/hush button on the Ei262 for up to 10 seconds. The
alarm will sound and then pause briefly while the RadioLINK signal is transmitted. The green power light
will turn red for this duration (approx 3.5 seconds). All other alarms should sound (this may take up to 20
seconds as the message may need to be relayed through repeaters). Release the test button. The local
alarm will cease and you should then be able to hear the other alarms sounding in the distance and then
stopping. Note: The local alarm may sound again depending on the number of repeaters in the system
as it acknowledges the repeated signals. Similarly check each RadioLINK device in the same way (if any
of the alarms do not sound, see - Section 14 Troubleshooting on page 36.